    NOTE

           This man page only documents the hardware-specific features of the
           safenet driver. For information about the core driver, see
           nutupsdrv(8).
    
    
    

    SUPPORTED HARDWARE

           This driver supports UPS equipment which can be controlled via SafeNet
           v1.0 for Windows (serial interface only).
    
    
    

    EXTRA ARGUMENTS

           This driver supports the following optional settings in the ups.conf(5)
           file:
    
           manufacturer=value
               Autodetection of this parameter is not possible yet (and it
               probably never will be). Therefore, this user-defined string
               accepts any name. The default is unknown.
    
           modelname=value
               Like manufacturer above. The default is unknown.
    
           serialnumber=value
               Like manufacturer above. The default is unknown.
    
           ondelay=value
               Time to wait before switching on the UPS (minutes). Defaults to 1
               minute.
    
           offdelay=value
               Time to wait before shutting down the UPS (seconds). Defaults to 30
               seconds.
    
    
    

    UPSCMD

           This driver supports some instant commands (see upscmd(8)):
    
           test.battery.start
               Start UPS self test
    
           test.battery.stop
               Cancel UPS self test
    
           test.failure.start
               Start simulated power failure
    
           test.failure.stop
               Cancel simulated power failure
    
           beeper.enable
               Enable the UPS beeper
    
           beeper.mute
               Temporarily mute the UPS beeper
    
           may stay on or switch off and not back on again. The shutdown.reboot
           command will unconditionally switch on the load again (with or without
           mains present).
    
           If the driver is called with the -k option (or through upsdrvctl
           shutdown) it tries to detect which command should be used in an attempt
           to stay off until mains is present again or to cycle the output if the
           power returned in the mean time. This isn't bullet-proof, and you
           should be prepared that the power will either not be shutdown, or that
           it doesn't return when the power comes back.
    
    
    

    AUTHOR

           Arjen de Korte <adkorte-guest at alioth.debian.org>
    
    
    

    SEE ALSO

       The core driver:
           nutupsdrv(8)
    
       Internet resources:
           The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
    
    
    

    Network UPS Tools 10/09/2011 SAFENET(8)

    
    
  • MORE RESOURCE


  • Linux

    The Distributions





    Linux

    The Software





    Linux

    The News



  • MARKETING






  • Toll Free

webmaster@linuxguruz.com
Copyright © 1999 - 2016 by LinuxGuruz